ELECTRONIC MEASUREMENT EQUIPMENT MECHANIC (T32)

Army National Guard Units logo
Army National Guard Units
ScreenedFull timeJust posted
Camp Ripley, Minnesota
$35.73 - $41.71 per hour
Posted 1 day ago
Apply Now

About the role

THIS IS AN ARMY NATIONAL GUARD TITLE 32 EXCEPTED SERVICE POSITION UNIT: FMS #9 LOCATION: Camp Ripley, Minnesota SELECTING OFFICIAL: CW3 Jacob Riggs (320)616-3063 ARMY NATIONAL GUARD MEMBERSHIP IS REQUIRED

Major Duties: This is not an all-inclusive list A ELECTRONIC MEASUREMENT EQUIPMENT MECHANIC (T32), WG-2602-11, (1) Calibrates and repairs TMDE within support capability and authority including various levels of calibration as designated in technical bulletins, manuals, etc. Performs functional electronic, physical, and radioactive testing involving interpretation and analysis of measurement data, in accordance with cyclic inspection requirements. Aligns, troubleshoots, tests, inspects, repairs, modifies, calibrates and certifies precision measurement equipment such as multimeters, microwave equipment, oscilloscopes, temperature analyzers, mercurial barometers, gage blocks and micrometer caliper dimensional equipment, digital voltmeters, signal generators, torque wrenches, pressure gauges, torque testers, weight scales, electronic counters, radiation monitors, radix calibrators, and radiation dosimeters. Analyzes and isolates component malfunctions; calculates and determines tolerances; and performs tests and calibrations in accordance with instructions, which are often vague and incomplete, and may require the preparation of diagrams and instructions to facilitate the calibration action. (2) Sets up system test sets and various types of test equipment such as frequency meters, standing wave ratio meters, radio frequency (RF) power meters, function/ arbitrary waveform generator, distortion analyzers, time frequency work stations, oscillators, voltmeters, electronic counters, oscilloscopes, attenuators, decade resistors and capacitors, signal generators, stroboscope, tachometers, pneumatic and hydraulic pressure standards and other physical and electronic tests. Diagnoses equipment, makes repairs, and replaces defective parts/components such as integrated circuits, printed circuit boards, electronic condition coils, radiation detector boards/circuits, crystals, transistors, tubes, transformers, condensers, diodes, relays potentiometers, and related components. (3) Following repair, tests by applying signals in known amplitude and wave shape into oscilloscopes to observe wave pattern. Isolates faults by taking measurements and comparisons in voltage, amperage, ohms, henries, power factor, watts, temperature, humidity, microns, foot-pounds, decibels, sensitivity, noise, stability, Voltage Standard Wave Ratio (VSWR), impedance, phase, absolute pressure, time intervals, displacement, flow rate, etc., to determine performance of equipment. If signal is distorted, traces it through electronic stages to locate malfunctioning part. Checks sweep rate by feeding known signal to an oscilloscope and observing wave pattern to correct shape and size. Operates equipment to complete range checking for proper operation of positioning controls. Adjusts with trimmer potentiometers; and if calibration is still not possible, adds or removes sufficient resistance to permit balancing of circuit. As needed, contacts the using organization to obtain information concerning the nature of the malfunction. (4) Determines purpose in operation characteristics of each major section. Refers to technical manuals and manufactures specifications to obtain information on operation characteristics of circuit components such as integrated circuits, microprocessors, decoders, latching networks, notch filters, logics, controllers, programmable gain amplifiers, digital displays, transistors, tubes, transformers, coils, relays, motors, and similar devices. Disassembles, cleans and inspects parts such as printed circuit boards, resistors, capacitors, integrated circuits, relays, chambers, cables, and wiring for evidence or wear or malfunction. Repairs and/or replaces parts as required. Uses special test devices and radioactive samples or other calibrated sources. Tests equipment for sensitivity and correct operation. Observes necessary precautions as stipulated in operational repair manuals. Makes radiation calculations/readings at various distances from the standard ensuring radiation equipment is operating in specified parameters. (5) Completes necessary Army Maintenance Management System (TAMMS), calibration, radiation reports and other records and forms on work completed. Ensures maximum number of weapons systems are operationally ready. Uses TMDE Integrated Maintenance Management Systems (TIMMS) for all supported equipment to track, turn-in, repair, calibrate, and return to the end user in a timely fashion to prevent work stoppages. Furnishes technical data to the supervisor for inclusion in reports as well as recommending equipment improvement and solutions for unusual problems related to testing and the use of precision TMDE. (6) Follows appropriate safety procedures, with special care being exercised while calibrating high voltage, radio frequency, radioactive sources and high-pressure Performs other duties as assigned. The above does not list all duties. The full list of duties can be provided upon request.

CONDITIONS OF EMPLOYMENT Minnesota National Guard Membership is required. If you are not sure you are eligible for military membership, please contact a National Guard recruiter prior to applying for this position. Applicants who are not currently a member of the MN National Guard must be eligible for immediate membership and employment in the National Guard in the military grade listed in this announcement. Selectee will be required to wear the military uniform. Federal employment suitability as determined by a background investigation. May be required to successfully complete a probationary period. Acceptance of an excepted service position constitutes concurrence with these requirements as a condition of employment. Must be able to obtain and maintain the appropriate security clearance of the position. Most MNNG position are covered by the Domestic Violence Misdemeanor Amendment (30 Sep 96) of the Gun Control Act (Lautenberg Amendment) of 1968. An individual convicted of a qualifying crime of domestic violence may not perform the duties of this position. Irregular and/or overtime (compensatory) hours may be required to support operational requirements or contingencies or may be required to work hours outside of the normal duty day. MILITARY COMPATIBILITY: Upon selection, individuals will undergo a background check to validate suitability for employment with the federal government as permitted by law, regulation, Presidential order or other authority. Suitability is dependent upon the particular requirements for security clearance, sensitivity level, and DOD IT network access. Items checked include, but are not limited to all criminal history record information, employment history, education and fiscal accountability/responsibility. The individual selected must be assigned to a compatible military position and must also maintain satisfactory membership in the Minnesota Army National Guard.

EDUCATION: NA You must provide transcripts or other documentation to support your Educational claims. To receive credit for Education, you must provide documentation of proof that you meet the Education requirements for this position.

About this listing

Screened by Joboru

This role passed our automated spam and quality filters and was active in our feed when last checked. Joboru is an aggregator — here is how we screen listings. If anything looks off, tell us.